SKW ACU
Highlights:
- Modular air handling units with side connection
- Integrated high efficient AcuBlock recovery
- T2/TB2/L1(M)/D1(M)/F9/C3 as standard
- From 500 m³/h to 32 000 m³/h
- Available in 44 sizes for the V2 classification
- Other sizes and airflows are available on request
- Available in stacked or side-by-side execution
- Exceptionally light and robust casing in special aluminium composite
- 55mm panel thickness and internal insulation made of heat-injected polyurethane foam with a density of 45-50 kg/m³ or oriented mineral-wool fibers with density of 100 kg/m³ resulting in ultra quiet housing
- Modern Plug & Play controller
- Control electrical cabinet with revision switch and touchscreen controller (FAD).
- FAD is a 3 ½” TFT touchscreen controller with BACnet® MS/TP communication
- Control cabinet can be mounted onto the AHU or away on the wall
- 6 Universal Input (UI)
- 12 Binary Input (BI)
- 4 Configurable Output (CO), Analog Output, Voltage Mode, 0–10 VDC
- 5 Relay Output (RO)
- Real-time switchable communications protocols from BACnet® MS/TP, N2 or Modbus through the onboard local display or Mobile Access Portal gateway
- BACnet Automatic Discovery support enables easy controller integration into any BACnet BAS system
- Support for Mobile Access Portal (MAP) gateway or Stationary Mobile Access Portal for ease of configuration and remote service tool
- Up to 100 devices One segment of BACnet MSTP
Available options:
- Integrated Heat-pump for Cooling or Reversible for cooling an additional heating
- Hot and cold water batteries, changeover or DX Batteries
- Silencers sections or external rectangular sound attenuators to be mounted on site
- Roof protection for outdoor installation
- “FlatPack” execution for transport and installation in tight spaces
- “Naked” execution without controls or wiring